TX® (C) 150/250(300) V
TX (C) 150/250V 1P0.75
Nexans ref. 10167362
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 6.1 mm
- Maximum outer diameter: 7.1 mm
- Approximate weight: 48 kg/km
TX (C) 150/250V 2P0.75
Nexans ref. 10167494
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.0 mm
- Maximum outer diameter: 8.2 mm
- Approximate weight: 71 kg/km
TX (C) 150/250V 3P0.75
Nexans ref. 10167497
- Packaging: Cut to length (m)
- Number of pairs: 3
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 9.6 mm
- Maximum outer diameter: 11.0 mm
- Approximate weight: 109 kg/km
TX (C) 150/250V 4P0.75
Nexans ref. 10167498
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 10.5 mm
- Maximum outer diameter: 12.0 mm
- Approximate weight: 131 kg/km
TX (C) 150/250V 7P0.75
Nexans ref. 10167502
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 14.5 mm
- Approximate weight: 205 kg/km
TX (C) 150/250V 10P0.75
Nexans ref. 10167505
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 17.0 mm
- Approximate weight: 282 kg/km
TX (C) 150/250V 14P0.75
Nexans ref. 10167507
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 17.0 mm
- Maximum outer diameter: 19.5 mm
- Approximate weight: 375 kg/km
TX (C) 150/250V 19P0.75
Nexans ref. 10167509
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 19.0 mm
- Maximum outer diameter: 23.0 mm
- Approximate weight: 483 kg/km
TX (C) 150/250V 24P0.75
Nexans ref. 10167510
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 21.5 mm
- Maximum outer diameter: 24.0 mm
- Approximate weight: 599 kg/km
TX (C) 150/250V 37P0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 37
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 25.5 mm
- Maximum outer diameter: 29.0 mm
- Approximate weight: 900 kg/km
TX (C) 150/250V 1T0.75
Nexans ref. 10167363
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 1
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 6.6 mm
- Maximum outer diameter: 7.6 mm
- Approximate weight: 58 kg/km
TX (C) 150/250V 2T0.75
Nexans ref. 10047812
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 10.0 mm
- Maximum outer diameter: 12.0 mm
- Approximate weight: 150 kg/km
TX (C) 150/250V 4T0.75
Nexans ref. 10047813
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 11.5 mm
- Maximum outer diameter: 13.5 mm
- Approximate weight: 190 kg/km
TX (C) 150/250V 7T0.75
Nexans ref. 10167504
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 17.0 mm
- Approximate weight: 310 kg/km
TX (C) 150/250V 10T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 10
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 17.0 mm
- Maximum outer diameter: 19.5 mm
- Approximate weight: 440 kg/km
TX (C) 150/250V 1P1.5
Nexans ref. 10167511
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 7.6 mm
- Maximum outer diameter: 8.8 mm
- Approximate weight: 80 kg/km
TX (C) 150/250V 2P1.5
Nexans ref. 10167513
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 8.6 mm
- Maximum outer diameter: 10.0 mm
- Approximate weight: 118 kg/km
TX (C) 150/250V 3P1.5
Nexans ref. 10167514
- Packaging: Cut to length (m)
- Number of pairs: 3
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 11.5 mm
- Maximum outer diameter: 13.5 mm
- Approximate weight: 179 kg/km
TX (C) 150/250V 4P1.5
Nexans ref. 10167515
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 15.0 mm
- Approximate weight: 230 kg/km
TX (C) 150/250V 7P1.5
Nexans ref. 10270142
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 16.0 mm
- Maximum outer diameter: 18.0 mm
- Approximate weight: 361 kg/km
TX (C) 150/250V 10P1.5
Nexans ref. 10167517
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 19.0 mm
- Maximum outer diameter: 21.5 mm
- Approximate weight: 501 kg/km
TX (C) 150/250V 14P1.5
Nexans ref. 10270133
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 21.5 mm
- Maximum outer diameter: 24.5 mm
- Approximate weight: 634 kg/km
TX (C) 150/250V 19P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 25.0 mm
- Maximum outer diameter: 28.0 mm
- Approximate weight: 910 kg/km
TX (C) 150/250V 2T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 15.0 mm
- Approximate weight: 240 kg/km
TX (C) 150/250V 4T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 16.5 mm
- Approximate weight: 320 kg/km
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TX® (C) 150/250 V overall screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables provide a medium protection aganist external electromagnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
- Conductor
Stranded bare copper class 2 - Insulation
XLPE (cross-linked polyethylene) - Collective screen
Alu/polyester tape with a tinned copper drain wire - Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour : grey
Marking
NEXANS 279 TX(C) Nber of pairs/triads & cross-section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat. A WW YYYY *CE* Manufacturing n°+ metric marking
Core Identification
Pair: white / blue with printed with pair number
Triad: white / blue / red with printed with triad number
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania